DESIGNING A LOW ANGLE X-RAY SCATTERING (LAXS) SYSTEM AND ITS USE IN

CHARACTERISATION OF SOME BIOMEDICAL MATERIALS

by

NAGI ABDALLAH HUSSEIN

Thesis submitted in fulfilment of the requirements for the degree of Doctor of Philosophy

May 2004

(2)

, -

II

(3)

ACKNOWLEDGEMENT

First of all, plentiful thanks are due to Allah lord of the worlds.

I would like to express my sincere gratitude to my supervisor Professor A. Shukri for his assistance, guidance and support. He was always listening and caring about my being and my family. I thank him for being my supervisor and I thank him for being an older brother to me. I would like to thank my co-supervisor Professor A. A. Tajuddin for his supervision, guidance and motivations and for his kind and encouraging words since the first time we have met. My appreciation also goes to Professor C. S. Chong for his encouragement and valuable scientific guidance and for all the fruitful discussions since the early days of the project.

I am deeply indebted to my parents for their prayers and patience. May Allah bless them, amen. Special gratitude and thanks goes to my wife for taken the burden of the whole family and for standing by my side and being the source of warmth and comfort.

I will never forget the joy and happiness that my sons have brought to me throughout this endeavour.

I would like to acknowledge the technical assistance and moral support provided by Mr.

Azmi Omar and Mr. Habib Marikan Bawasah. The contribution and assistance of Dr. J;) ..

Bradley is greatly appreciated. The help provided by other lab. assistants and the machine workshop is also acknowledged. Finally, I would like to thank all my friends and colleagues who supported me one-way or the other and wish them all every success.

III

(4)

TABLE OF CONTENTS

Acknowledgement iii

Table of Contents IV

List of Tables VIII

List of Figures IX

List of Symbols xv

Abstrak XIX

Abstract xxii

CHAPTER ONE Introduction 1

1.1 Introduction 1

1.2 Coherent scattering 3

1.3 Low angle coherent scattering 4

IA Applications ofLAXS 7

lA.l Computed tomography 8

IA.2 Bone analysis and mineral density determination 8 1.4.3 Characterisation of biomedical material and diagnostic radiology 9 '

IAA Characterisation of other materials 9

lA.5 Food industry 9

IA.6 Detection of explosives 9

1.4.7 Others 10

1. 5 Scope of work 10

1.6 Objectives 11

iv

(5)

CHAPTER TWO Theoretical Background 2.1 Interaction of X-rays with matter

2.1.1 Photoelectric effect 2.1.2 Compton scattering 2.1.3 Pair production 2.1.4 Rayleigh scattering

2.1.5 Nuclear Thomson scattering 2.1.6 Delbruck scattering

2.1.7 Nuclear resonance scattering 2.1.8 Photo disintegration of nuclei 2.1.9 Meson production

2.2 Principles of X-ray scattering 2.2.1 Introduction

2.2.2 Scattering of X-rays by single electron "Thomson scattering"

2.2.3 Scattering of X-rays by an atom "Rayleigh scattering 2.2.3.1 The atomic form factor

2.2.3.2 Correction of the atomic form factor 2.2.4 Scattering of X-rays by many atoms

2.2.4.1 Scattering by a molecule 2.2.4.2 Scattering by multi atoms

CHAPTER THREE Experimental Review 3.1 Experimental parameters

3.1.1 Introduction 3.1.2 Photon sources 3.1.3 Scattering material 3.1.4 Methods of detection

3.1.4.1 Photographic films 3.1.4.2 Gas counters

3.1.4.3 Scintillation detectors 3.1.4.4 Semiconductor detectors 3.1.5 Shielding and collimation 3.2 Review of previous experiments

3.2.1 Introduction 3.2.2 Aim of experiment

3.2.2.1 Tomography

3.2.2.2 Characterisation of materials 3.2.2.3 Determination of bone density

3.2.2.4 Characterisation of biological materials 3.2.2.5 Detection of explosives

3.2.3 Techniques involved in scattering experiments 3.2.4 Photon source

3.2.5 Collimation and shielding 3.2.6 Samples

3.2.7 Detectors

3.2.8 Measured and analysed parameters 3.2.9 Energy dispersive vs. angular dispersive

v

12 12 14 14 15 15 16 16 17 17 17 17 17 18 24 25 28 29 29 30

32 32 32 32 33 34 34 35 35 36 38 39 39 39 39

40

40

40

41 41 41 42 43

44

45 46
(6)

CtlAYl~K ~UlJK LAX:S :system: Design, Testing and Optimisation Aspects 47

4.1 Experimental set up of LAXS system 47

4.1.1 X-ray source 47

4.1.1.1 X-ray tube 47

4.1.1.2 Generator 48

4.1.1.3 X-ray beam profile 48

4. 1.2 Collimation and shielding assembly 51

4. 1.3 Detection and data acquisition system 54

4. I .3.1 Components description 54

4.1.3.2 Detector characterisation 54

4.1.4 Target assembly and orientation 61

4.1.5 Beam and collimator alignment 61

4.2 Optimisation of the LAXS system 62

4.2.1 Introduction 62

4.2.2 Materials and methods 62

4.2.3 Analysis of results 64

4.2.3.1 Scattering angle 64

4.2.3.2 Collimation 65

4.2.3.3 Tube current, applied voltage, and acquisition time 66

4.2.3.4 Correction factors 67

4.2.3.5 Criteria for parameter selection' 67

CHAPTER FIVE Results and Discussion 5.1 Application I: Studies of trabecular bone degradation

5.1.1 Introduction 5.1.2 Objectives

5.1.3 Materials and methods 5.1.3.1 Phantom preparation 5.1.3.2 Experimental set up 5.1.4 Analysis of results

5.1.4.1 Selection of optimal scattering angle

5.1.4.2 Angular and energy distribution scattering spectra 5.1.4.3 Minimisation of exposure time

5.1.4.4 Parameters

5.2 Application II: Investigation of cortical bone loss 5.2.1 Introduction

5.2.2 Objectives

5.2.3 Materials and methods 5.2.3.1 Phantom description 5.2.3.2 Experimental set up 5.2.4 Results and discussion

5.2.4. I Analysis of powdered aluminium phantoms 5.2.4.2 Analysis of solid aluminium phantoms

5.3 Application III: Identification of some substances by evaluating their interatomic spacing constants

5.3.1 Introduction 5.3.2 Objectives

vi

78

78 78 80 80 80 82 82 82 86 88 90 94 94 95 95 95 97, 97 97 107 114, 114 1 14

(7)

5.3.3 Materials and methods 114

5.3.4 Analysis of results 115

5.3.4.1 Optimising the measuring apparatus I 15

5.3.4.2 Determination of interatomic spacing of some substances I 18 5.4 Application IV: Characterisation of some biomedical materials 120

5.4.1 Introduction 120

5.4.2 Objectives 120

5.4.3 Materials and methods 120

5.4.4 Spectra analysis 122

5.5 Application V: Examination of the sensitivities of LAXS system 135 using K2HP04 solutions

5.5.1 Introduction 135

5.5.2 Objectives 135

5.5.3 Materials and methods 136

5.5.4 Analysis and discussion of results 136

5.6 Application VI: The effect of thickness on the LAXS diffraction spectra. 140

5.6.1 Introduction 140

5.6.2 Materials and methods 140

5.6.3 Analysis and discussion of results 140

5.7 Application VII: Determination of differential cross section of some 146 biomedical materials

5.7.1 Introduction 146

5.7.2 Objective 147

5.7.3 Materials and methods 147

5.7.3.1 Materials 147

5.7.3.2 Experimental apparatus 147

5.7.4 Basic theory and data correction 148

5.7.5 Results and discussion 150

CHAPTER SIX Conclusion and Future Work 6.1 Conclusion

6.2 Future works

6.2.1 Technical aspect 6.2.2 Applications REFERENCES

vii

154 154 157 157 158 158

(8)

LIST OF TABLES

Table 2.1. Type and effect of possible interaction processes. 13

Table 4.1. Range of values of the examined parameters. 63

Table 5.1. Concentrations of aluminium powder and wax in the various mixtures 82 of finger phantom samples.

Table 5.2. Aluminium rod diameter and wax shell thickness values for five 95 samples that are used to simulate cortical bone loss for first type

phantoms.

Table 5.3. Aluminium rod diameter and wax shell thickness values for eight 96 samples that are used to simulate cortical bone loss for second type

phantoms.

Table 5.4. Comparison between the measured and corrected scattering angles 117 together with the percentage error in d spacing at three collimator

sizes.

Table 5.5. Comparison ofthe measured and published interatomic spacing 119 constant of some substances and their relative percentage errors.

Table 5.6. List ofthe relevant properties of the examined biomedical substances. 121

Table 5.7. Calculated and published values of interatomic spacings of aluminium. 142

viii

(9)

LIST OF FIGURES

Fig. 2.1 Coordinate axes and observer points for EM wave of electric field E. 20

Fig.4.1 Schematic diagram of the LAXS system. 48

Fig. 4.2 Schematic diagram of the setup used for X-ray beam profile 49 examination.

Fig. 4.3 Image size (diameter) vs. image distance from source collimator. 50 Fig. 4.4 Optical density vs. distance across image. 50 Fig. 4.5 Correlation between image sizes from OD curve and manual 51

measurements.

Fig. 4.6 A photograph of the LAXS system setup at the Biophysics Lab. 52 Fig. 4.7 Photographs show, top: examples of both types oflead plug collimators 53

and their various sizes and bottom: the opposite face and side view of slit collimator.

Fig. 4.8 Schematic diagram of detection and data acquisition system. 57

Fig. 4.9 Cross section of LEGe detector. 57

Fig. 4.10 Energy calibration curve of LEGe detector. 58

Fig.4.11 Percentage deviation from linearity vs. energy for LEGe detector. 58 Fig. 4.12 Minimum percentage deviation from linearity vs. shaping time for 59

LEGe detector.

Fig. 4.13 FWHM vs. energy for LEGe detector (-r=6 ~s). 59 Fig. 4.14 FWTM vs. energy for LEGe detector (,=6 ~s). 60 Fig. 4.15 Ratio of FWTM/FWHM vs. energy for LEGe detector (-r=6 ~lS) 60 Fig.4.16 Labelled scattering spectra ofCaC03 at 9° using 2mm slit (t=900 s). 63 Fig. 4.17 Peak energy vs. scattering angle for the labelled diffraction peaks. 69

IX

(10)

1

Fig. 4.18 Peak energy vs. - . - g - for the labelled diffraction peaks. 69 SIn :2

Fig. 4.19 Normalised total counts of scattering spectrum vs. scattering angle 70 using 2 mm slit for 900 sec.

Fig. 4.20 Peak areas vs. scattering using 1.5 mm slit for 900 sec. 70 Fig. 4.21 FWHM vs. scattering angle using 1.5 mm slit for 900 sec. 71 Fig. 4.22 Position of peak "a" vs. size of slit at various scattering angles. 71 Fig. 4.23 Position of peak "a" vs. size of pinhole at various scattering angles 72 Fig. 4.24 Normalised peak intensity with respect to highest value "a" vs. size of 72

slit at various scattering angles.

Fig. 4.25 Normalised peak intensity "a" with respect to highest value vs. size of 73 pinhole at various scattering angles.

Fig. 4.26 Normalised total area under the spectrum with respect to highest value 73 of 4 mm slit collimator vs. size of slit at various scattering angles.

Fig. 4.27 Normalised total area under the spectrum with respect to highest value 74 of 4 mm slit collimator vs. size of pinhole at various scattering angles.

Fig. 4.28 Normalised total area with respect to the highest value of 4 mm slit 74 collimator vs. scattering angle for slit and pinhole collimators of

various sizes.

Fig. 4.29 FWHM of peak "a" vs. size of slit collimator at various scattering 75 angles.

Fig. 4.30 FWHM of peak "a" vs. size of pinhole collimator at various scattering 75 angles.

Fig. 4.31 Normalised total counts of scattering spectra with respect to the highest 76 value vs. scattering angles at four different values of tube current

while applied voltage and collection time are kept constant. Solid lines are fitted curves.

Fig. 4.32 Normalised total counts of scattering spectra with respect to the highest 76 value vs. scattering angles at two different values of applied voltage while tube current and collection time are kept constant.

Fig. 4.33. Normalised scattering spectra with respect to the highest at two 77 different values of applied voltage while tube current and collection

time are kept constant.

x

(11)

Fig. 4.34 Normalised total counts of scattering spectra with respect to the highest 77 value vs. scattering angles at four different values of collection time while applied voltage and tube current are kept constant. Solid lines are fitted curves.

Fig. 5.1 A photograph shows the preparation of trabecular and cortical bone 81

Fig. 5.2 Fig. 5.3

Fig. 5.4

Fig. 5.5

Fig. 5.6

Fig. 5.7

Fig. 5.8

Fig. 5.9

Fig. 5.10

Fig.5.11

Fig. 5.12

Fig.5.l3

substitute phantoms. Basic materials of powdered aluminium, wax and their mixture (middle) will be introduced into an empty wax finger phantom and secured by plastic cover (bottom). Phantoms, which are used to simulate cortical bone by employing solid aluminium rods of different thicknesses, are shown (top).

Scattering spectra of sample 7 at scattering angles 30_100.

Diffraction patterns at scattering angle of

r

normalised relative to the largest peak value.

Angular distribution scattering spectra for four bone finger phantoms with increasing percentage of trabecular bone substitute (AI powder) the first contains pure bone marrow substitute (wax).

Counts under trabecular bone peak vs. percentage of trabecular bone substitute at exposure time of 300 s_

Counts under trabecular bone peak vs. percentage of trabecular bone substitute at several exposure times.

Ratio of counts under the trabecular bone peak to total spectrum vs.

percentage of trabecular bone substitute at several exposure times.

Linear fit lines are shown.

Ratio of Al peak to total counts (left) and logarithm of ratio (right) vs.

percentage of trabecular bone substitute.

Logarithm of ratio of Al peak to total counts vs. percentage of trabecular bone substitute at several exposure times.

Ratio of Al peak to wax peak (A) and logarithm of ratio (B) vs.

percentage of trabecular bone substitute.

Logarithm of ratio of Al peak to wax peak vs. percentage of trabecular bone substitute at several exposure times.

Diffraction patterns of bone phantoms obtained at 7° scattering angle.

Each pattern is normalised relative to its highest counts. Sample I and 8 are wax and aluminium powder only.

Energy peak positions of aluminium powder and wax components for all samples.

xi

83 85

86

88

90

91

92

92

93

93

,

100

101

(12)

Fig. 5.14 Normalised integrated spectrum (2-52 ke V) at 7° scattering angle vs. 101 diameter of aluminium powder for all samples.

Fig. 5.15 Normalised integrated spectrum (11-50 keY) at 7° scattering angle vs. 102 diameter of aluminium powder for all samples.

Fig. 5.16 Logarithm of normalised integrated spectrum (2-52 ke V) at 7° 102 scattering angle vs. diameter of aluminium powder for all samples.

Fig. 5.17 Normalised peak area of aluminium powder vs. its diameter at 7° 103 scattering angle for all samples.

Fig. 5.18 Amplitude of aluminium powder peak vs. its diameter at 7° scattering 103 angle for all samples.

Fig. 5.19 Ratio of aluminium PQwder peak to total counts vs. aluminium powder 104 diameter at 7° scattering angle for all samples.

Fig. 5.20 Square root of the ratio of aluminium powder peak to total counts vs. 104 aluminium powder diameter at 7° ~cattering angle for all samples.

Fig. 5.21 Ratio of aluminium powder to wax peak to vs. aluminium powder 105 diameter at 7° scattering angle for aJl samples.

Fig. 5.22 Square root of the ratio of aluminium powder to wax peak vs. 105 aluminium powder diameter at 7° scattering angle for all samples.

Fig. 5.23 Normalised peak area of wax component vs. its shell thickness at 7° 106 scattering angle for all samples.

Fig. 5.24 FWHM of aluminium powder and wax peaks at 7° scattering angle for 106 all samples.

Fig. 5.25 Diffraction patterns of bone phantoms with solid aluminium rod 109 obtained at 1 OOscattering angle and using 4 mm pinhole collimators.

Each pattern is normalised relative to its highest counts. Sample (i) contains wax component only.

Fig.5.26 Diffraction patterns of bone phantoms obtained at IOOscattering angle 110 and using 2 mm slit collimators.

Fig. 5.27 Normalised integrated -spectrum (2-52 ke V) at 10° scattering angle and 110 4 mm pinhole collimators vs. diameter of aluminium rods for all

samples.

Fig. 5.28 Logarithm of normalised integrated spectrum (2-52 keY) at 10° 111 scattering angle and 4 mm pinhole collimators vs. diameter of

aluminium rods for all samples.

xii

(13)

rIg. J.L':J l'wrmallsed area under the 32 keY and 36 keY peaks at 10° scattering III angle and 4 mm pinhole collimators vs. diameter of aluminium rods

for all samples.

Fig. 5.30 FWHM of the 32 keY and 36 keY peaks at 10° scattering angle and 4 112 mm pinhole collimators vs. diameter of aluminium rods for all

samples.

Fig. 5.31 Normalised area under the 18 keY and 20 keY peaks at 10° scattering 112 angle and 4 mm pinhole collimators vs. thickness of wax shell for all

samples.

Fig. 5.32 Normalised area under the 18 keY and 20 keY peaks at 10° scattering 113 angle and 4 mm pinhole collimators vs. thickness of wax shell for all

samples.

Fig. 5.33 FWHM of the 18 keY and 20 keY peaks at 10° scattering angle and 4 113 mm pinhole collimators vs. thickness of wax shell for all samples.

Fig. 5.34 Diffraction spectrum of CaC03 • . J 26

Fig. 5.35 Diffraction spectrum of K2HP04 solution of density 1.48 g/cm3 J 26

Fig. 5.36 Diffraction spectrum of powdered K2HP04 127

Fig. 5.37 Diffraction spectrum of paraffin wax 127

Fig. 5.38 Diffraction spectrum ofPMMA. 128

Fig. 5.39 Diffraction spectrum of aluminium. 128

Fig. 5.40 Diffraction spectrum of polyethylene. 129

Fig. 5.41 Diffraction spectrum of copper. 129

Fig. 5.42 Diffraction spectrum of rubber. J 30

Fig. 5.43 Diffraction spectrum of bone phantom. J 30

Fig. 5.44 Diffraction spectrum of dried chicken bone. 131 Fig. 5.45 Diffi"action spectrum of dried chicken bone in wax. J 31 Fig. 5.46 Diffraction spectrum of fresh chicken bone with tissue. J 32 Fig. 5.47 Diffraction spectrum of fresh chicken bone with tissue removed. J 32 Fig. 5.48 Diffraction spectrum of fresh chicken tissue. 133

Fig. 5.49 Diffraction spectrum of water. J 33

....

XIII

(14)

Fig. 5.50 Diffraction spectra of dried chicken bone and empty plastic bottle at

r

134 Fig. 5.51 Diffraction spectra offresh chicken; bone with tissue, bone only and 134

tissue only at 7° scattering angle.

Fig. 5.52 Diffraction spectra at 10° scattering angle of K2HP04 (a) powder (b) 138 solution.

Fig. 5.53 Integrated counts of diffraction spectra of K2HP04 solutions at

r

138

scattering angle normalised relative to water vs. density of the solutions

Fig. 5.54 Comparison between logarithm of the ratio of total scattered spectrum 139 of K2HP04 solution to that of water vs. its density for several

scattering angles.

Fig. 5.55 Comparison between logarithm ofthe ratio of total scattered spectrum 139 ofK2HP04 solution to that of water vs. its concentration for several

scattering angles.

Fig. 5.56 Examples of diffraction spectra of afuminium sheets at various 143 thicknesses measured at 10° scattering angle.

Fig. 5.57 Examples of diffraction spectra of copper sheets at various thicknesses 144 measured at 10° scattering angle.

Fig. 5.58 The integrated diffraction spectra, normalised peak areas and sum of 145 peaks of aluminium sheets vs. sheet thicknesses measured at 10°

scattering angle.

Fig. 5.59 The integrated diffraction spectra, normalised peak areas and sum of 145 peaks of copper sheets vs. sheet thicknesses measured at 10°

scattering angle.

Fig. 5.60 Comparison between form factor F2(q) and incoherent scattering 151 function Seq) using lAM values for PMMA.

Fig. 5.61 Measured linear differential scattering coefficient for PMMA. 151 Fig. 5.62 Measured linear differential scattering coefficient for polyethylene. 152 Fig. 5.63 Measured linear differential scattering coefficient for water. 152 Fig. 5.64 Measured linear differential scattering coefficient for paraffin wax. 153 Fig. 5.65 Measured linear differential scattering coefficient for rubber. 153

xiv

(15)

LIST OF SYMBOLS

~ Attenuation coefficient

p Physical density

d Interatomic spacing

e

Scattering angle

n Order of diffraction

"-

Wave length

Intensity of X-ray beam 10 Initial intensity of X-ray beam

E Energy of photon

NA

Avogadro's number

h Planck constant

c Velocity of light

T Kinetic energy

BE Binding Energy

xv

(16)

mo e

d ()

Th

dO.

F (q)

/', /"

g(q) Seq)

E

"

u

M

z

Rest mass of electron Electron charge

Rayleigh differential scattering cross section

Thomson differential scattering cross section

Compton differential scattering cross section

Atomic form factor

Dispersion or anOJp,alous correction Molecular form factor

Interference function

Incoherent scattering function

Electric field

Unit vector, which represents the polarization of electric field,

Amplitude of the electric field Atomic or molecular mass Atomic number

"

XVI

(17)

k k

OJ

FWHM FWTM

p

x r

t a

No J1(q)

A

Q

I(q) C(q) Bg(q)

Wave vector along direction of propagation

Wave number equals the magnitude wave vector

Angular frequency

Full Width at Half Maximum Full Width at Third Maximum Photon momentum

Permittivity of free space Thickness

Distance Time Acceleration

Number of scattering centres

Linear differential scattering coefficient Cross sectional area

Solid angle

Classical electron radius or Thomson scattering length

Final corrected diffraction pattern count Primary photon count

Background counts

XVII

(18)

;;:, T(q) Attenuation correction factor SS(q) Incident spectrum shape factor

H Normalisation factor

O"T

Thomson cross section

O"KN

Klein-Nishina cross section

p

Polarization factor

PeA

Electron density function

per)

Number of electrons per unit volume.

¢

Phase difference

<D

Resultant phase difference

Q

Wave vector transfer

0A

Total scattering length

xviii

(19)

MEREKABENTUK SISTEM SERAKAN SINAR-X SUDUT RENDAH (LAXS) DAN PENGGUNAANNY A DALAM

PENCIRIAN BEBERAPA BAHAN BIOPERUBATAN

ABSTRAK

Serakan foton sinar-X yang bertenaga diagnostik «140 keY), pad a sudut serakan keeil

«12° ), daripada bahan Z rendah, seeara umumnya berbentuk koheren. Ciri kekoherenan ini akan membawa kepada kesan interferens antara foton-foton yang terserak itu untuk menghasilkan eorak belauan yang mempunyai kaitan dengan struktur antara-atom dan struktur antara-molekul medium serakan.

Corak-eorak belauan ini menjadi tanda khusu's bagi bahan yang mengalami saling tindakan berkaitan dan dengan itu boleh digunakan untuk meneirikan bahan tersebut.

Corak belauan dalam kajian ini dihasilkan melalui kaedah sebaran tenaga di mana foton berbilang tenaga daripada tiub sinar-X menghentam suatu sasaran pada sudut keeil tertentu, justeru gelaran Serakan Sinar-X Sudut Rendah (LAXS). Kaedah 1111 Juga digelar kaedah Belauan Sinar-X Sebaran Tenaga (EDXRD).

Sistem LAXS yang mematuhi prinsip-prinsip di atas telah dibina di Makmal Biofizik, Pusat Pengajian Sains Fizik, USM. Sistem tersebut terdiri daripada satu tiub sinar-X, pemasangan pengkolimat dan sasaran, pemerisaian, kelengkapan pengesanan dan kelengkapan pemerolehan data. Prestasi setiap komponen individu dalam sistem tersebut telah diuji berasingan dan eiri-eiri masing-masing direkod untuk penggunaan optimum. Sistem LAXS seterusnya diperiksa sebagai pemasangan sepadu. Penjajaran foton tuju dengan foton serakan melalui pengkolimat plumbum yang telah dibina, kearah pengesan LEGe merupakan aspek yang paling meneabar bagi kajian eksperimen tersebut.

XIX

(20)

Hasil pengoptlmuman geometn bag! slstem LAXS untuk membuat keputusan tentang parameter prestasi yang terbaik boleh dirumuskan seperti berikut: tiub sinar-X harus di gunakan pada voltan gunaan 50 kV dan arus 25 rnA untuk tempoh pengumpulan selama 300 saat menggunakan pengkolimat eelah 2 mm dan pad a sudut serakan 8° ,9° atau 10° untuk jarak tertentu yang dipilih. Kriteria yang dipilih untuk pemilihan ini adalah untuk meneapai keamatan eorak belauan yang tinggi dengan puneak-puneak yang sedia terIerai dan mengandungi sebanyak mungkin perine ian puneak dalam masa sesingkat mungkin.

Sistem LAXS telah digunakan dalam kajian fantom tulang yang telah difabrikasi. yang menyerupai perubahan ketumpatan tulang dalam osteoporosis. Fantom-fantom telah difabrikasi untuk mensimulasikan kehilangan tulang trabekular dan kehilangan tulang kortikal. Sistem LAXS didapati berupaya untuk.membezakan antara berbagai kepekatan eampuran untuk fantom-fantom tersebut dengan membandingkan eorak EDXRD.

Beberapa parameter kuantitatif yang mengaitkan komposisi fantom dengan eiri linear yang baik telah diwujudkan. Pengurangan dos yang diterima oleh sasaran untuk pengukuran in vivo masa hadapan telah diea~ai melalui pengurangan masa pengumpulan tanpa kehilangan kelinearan atau kepekaan.

Contoh beberapa bahan gantian bioperubatan dan biobahan seperti air, PMMA, LLDPE, getah, tulang yang dikeringkan, tulang segar, tisu dan bahan lain telah dikaj i dalam setup LAXS dan eorak belauan dianalisis. Corak belaun menggambarkan struktur dan komposisi bahan. Dengan itu ianya boleh digunakan sebagai eorak khusus untuk prosedur pengeeaman pangkalan data masa hadapan. Bahan fantom tulang yaqg difabrikasi menghasilkan eorak belauan yang serupa dengan eorak tulang sebenar.

Pekali serakan kebezaan linear bagi bahan-bahan gantian bioperubatan tersebut telah di ukur.

xx

(21)

Sebatian, campuran, logam, larutan, serbuk dan pepejal menghasilkan corak belauan tanda yang mempamerkan ketertiban struktur yang amorfus, semi amorfus atau hablur.

lni juga menunjukkan versatiliti sistem LAXS.

Sistem LAXS tersebut telah digunakan untuk mengecam bahan dengan menilaikan ruang antara-atom dan membandingkan dengan fail PDF dengan kelebihan masa pengumpulan yang pantas berbanding peleraian. Kesan ketebalan ke atas corak belauan telah dikaji untuk menentukan ketebalan optimum bagi bahan serakan. Aluminium dan kuprum digunakan untuk tujuan ini. Di samping itu kesan kepekatan dan ketumpatan larutan dikaji dengan ketumpatanjelas lebih sensitif.

XXI

(22)

ABSTRACT

Scattering of X-rays photons from low Z materials at diagnostic energies « 140 ke V) and low scattering angles «12°) is mainly coherent in nature. This coherence property will lead to interference effects between these scattered photons resulting in diffraction patterns, which are related to the interatomic and intermolecular structure of the scattering medium.

These diffraction patterns are unique signatures pf the interacted materials and therefore can be used to characterise them. Diffraction patterns in this work are produced by the energy dispersive method where polyenergetic photons from an X-ray tube impinge on a target at a fixed low angles and hence the names Low Angle X-ray Scattering (LAXS). This method is also referred to as the Energy Dispersive X-Ray Diffraction (EDXRD) method.

A LAXS system that complies with the above principles has been constructed at the Biophysics Laboratory, School of Physics, USM. The system comprises an X-ray tube, collimators and target assembly, shielding, detection and data acquisition equipments.

The performance of each individual component in the setup has been tested separately and its characteristics are recorded for optimal use. The LAXS system was the,n examined as an integrated assembly. Alignment of the incident and scattered photons through the manufactured lead collimators and into the LEGe detector was the most challenging aspect of the experimental work.

XXII

(23)

The results of geometrical optimisation of the LAXS system to decide on the best performance parameters can be summarised as follows: the X-ray tube should be working at an applied voltage of 50 kV and current of 25 rnA for collection period of 300 seconds using 2 mm slit collimators and at scattering angles of 8°, 9°or 10° for certain employed distances. The criteria taken for this selection are to obtain highly intense diffraction pattern with well-resolved peaks and contain as much as possible peak details in the shortest time possible.

The LAXS system has been utilised in studying fabricated bone phantoms, which mimic the changes of bone density during osteoporosis. Phantoms were fabricated to simulate trabecular bone loss and cortical bone loss. The LAXS system was found capable to disti-nguish between the various mixture concentrations of theses phantoms by comparing their EDXRD patterns. Several quantitative parameters that relate to the composition of the phantoms with good linear behaviour have been established.

Reduction in dose received by the target for future in vivo measurements was accomplished by the reduction in collection time without the loss of linearity or sensitivity.

Examples of some biomedical su1J.stitute materials and biomaterials such as water, PMMA, LLDPE, rubber, dried bone, fresh bone, tissue and others have been examined in the LAXS setup and their diffraction patterns analysed. The diffraction patterns reflected the structure and composition of the materials so that they can be used as signature patterns for future database identification procedures. Fabricated bone phantom materials gave diffraction patterns which closely resemble real bone pattern;;.

The linear differential scattering coefficient of these biomedical substitute materials have been measured.

XXlll

(24)

Compounds, mixtures, metals, solutions, liquids, powders and solids produced signature diffraction patterns that reflect their structural order being amorphous, semi amorpholls or crystalline. This also serves to show the versatility of the LAXS system.

The LAXS system has been used to identify materials by evaluating their interatomic spacings and comparing them with PDF files with the advantage of fast collection time over resolution. The effect of thickness on the diffraction patterns were investigated to determine the optimal thickness of the scattering material, Aluminium and copper were used for this purpose. In addition the effect of concentration and density of solutions samples were investigated with density appearing to be more sensitive.

xxiv

(25)

CHAPTER ONE Introduction

1. 1 Introduction

Even before the discovery of X-rays by Roentgen in 1895, there was some scientific work on radiation scattering by Lord Rayleig~, and others but it was concerned with light scattering (Strutt, 1871 a, 1871 b). The first work on X-ray scattering by free electrons was conducted by Thomson (1906).

The subject of scattering of X-rays by crystals was addressed by Darwin (1914) among others. Bragg and Bragg got the Nobel Prize (1915) on their experimental work on X- ray diffraction. The theoretical treatment of X-ray diffraction was established soon by Ewald (1916, 1917) and then by Von Laue (193], 1935).

X-ray diffraction technique was, and still being employed, as a method for characterisation of crystalline materials; the familiar subject of crystallography. X-ray diffraction by large molecules, which show non-crystallinity with some order on the local scale, was also tackled. Since the spacing of such molecules is quite large in trye order of tens and hundreds of interatomic spacing, and by inspection of the well known Bragg diffraction equation, the restriction to the use of small scattering angle 8 is clearly observed, (Guinier and Fournet, 1955). The use of a larger X-ray wavelength Ie is another alternative approach to small angle scattering, but in this case, X-ray absorption

(26)

WIll oe grear as TO OImlnISn me IntensIty or the dJrtracted beam and hence burden the detector employed with such long wavelengths.

In addition to X-ray diffraction, X-ray radiation was used in imaging since the day of its discovery. The field of radiology is a well-established science. However. X-ray scattering in this field is considered a problem, (Magalhaes et af.. 1995) that reduces contrast and signal to noise ratio of the image and therefore, leads to low quality images. Such problematic scattering must be overcome and various procedures were used in order to minimise the effect of scattering and preserve image quality (Moore el al., 1976; Stonestrom and Macovski, 1976; Rudin and Bednarek; 1980, Cack, 1981;

Joseph and Spital, 1981; and Magalhaes et al., 1995).

Characterisation of biomedical materials such ~s in the investigation of bone density using gamma-rays based on the transmission. technique were done by Cameron and Sorenson (1963), Roos et al. (1970), West and Reed (1970), Sorenson and Mazess (1970), Bradley et al. (1986) and Mooney and Speller (1992) and in the characterisation of other materials by Mancini (1985) and Bradley et af. (1986). X-rays were also employed in this area in the work of Buchnea et af. (1982).

Due to the dominance of scattering cross sections over absorption cross sections for common materials and in the radiological energy range of interest 0 - 140 ke V (Holt ef af., 1983, 1984 and Chong, 1989), scattering can be a useful tool in characterisation of materials using these energies.

Incoherent scattering is employed 111 the characterisation of materials in addition to transmission by several authors such as Clarke and Van Dyke (1973). Webber and Kennett (1976), and Chong (1989). The use of the ratio of the coherent to the incoherent scattered photons in the determination of bone density was the work of many authors such as Puumalainen et al. (1976), Kerr et al. (1980), Ling et af. (1982), Puumalainen ef

2

(27)

al. (1982) and Mossop et al. (1987), and in the characterisation of other materials by the authors Holt et aZ. (1983), Holt et aZ. (1984), Manninen et al. (1984), Webster and Lillicrap (1985) Webster et aZ. (1986), Confalonieri et al. (1987), and Shakeshaft et al.

(1997). Compton scattering alone was used for the purpose of imaging by Holt et of.

(1984), and Harding and Tischler (1986) and for identification of materials by Magalhaes et af. (1995) or their densities by Sharaf (2001). Coherent scattering as a single process was used to measure bone density by Kerr et af. (1980), and Ndlovu et of.

(1991). The Back scattering technique was employed by Mohammadi (1981). Wolf and Munro (1985), Confalonieri et aZ. (1987), Tuzi and Sato (1990), El-Kateb and Shehadah (1993), Tartari et aZ. (1994), Elyaseery and Chong (1995), Yacouti et af. (1997), and Morgan et aZ. (1998) for the identification of m'Jterials.

1.2 Coherent scattering

Coherent scattering has been dismissed as a process for identification of materials because of its small contribution to attenuation coefficient compared with incoherent scattering. Coherent scattered radiation does not depend on energy and its angular dependence is forward peaking, i.e. the differential scattering probabi I ity is peaked at zero and therefore indistinguishable from transmitted radiation, and in such cases it is a reducing quality process (Neitzel et al., 1985).

However, calculations by Johns and Yaffe (1983) using single scatter shovved that in the diagnostic energy range, the differential scattering cross section for coherent scattering did not peak at zero angle as it was previously believed but at an angle larger than zero. In fact, the differential coherent scattering cross section at zero degJ'ees almost vanishes. The work of the above authors was concerned with water, concluded that the maximum scattering probability occurred at an angle equals to 3.80 for photon energy of 60 keY, which is attributed to intermolecular interference. Their work also

3

(28)

showed that coherent scattering was much greater than incoherent scattering at low angles, and it contributed significantly to the total scattering process.

Morin and Berroir (1983) also showed that the forward peaking occurs at a non-zero angle for water samples, and the ratio of a single scattered photon to transmitted one is energy dependent with a significant contribution from Rayleigh scattering to this single scatter. The experimental work carried out by Muntz et af. (1983) confirmed the forward peaking of differential scattering cross sections at low angles and showed that the positions of the peaks depends on the structure of the material and depends sl ightly on the energy. So far, only single scatter is being considered while in real systems (thick objects) multiple scattering always occurs.

The work reported by Neitzel et aZ. (1985) usiQg Monte Carlo simulation showed the existence of incoherent multiple scattering, but the dominance is still to single scatter for these thick objects when polyenergetic radiation was used. This work also confirmed the forward peaking of coherent scattering probability at low scattering angles away from the transmitted radiation, and the broadening of the peak of interest with increasing sample thickness.

1.3 Low angle coherent scattering

An X-ray photon can interact with matter through various processes. Photoelectric effect and Compton (inelastic) scattering are the most common interactions. The most important interaction processes are dealt with in the next chapter.

There exist a type of interaction -where the scattering of X -rays photons in the energy range of about 140 keY or less and at low scattering angles « 12°) will be mainly coherent with no energy change involved in the process. This interaction is called coherent elastic scattering or historically known as Rayleigh scattering. X-ray scattering

4

(29)

at low angles is considered to be a coherent or elastic process due to the high probability of its cross section over incoherent (inelastic) Compton scattering cross section.

Scattering can be from a single free electron, the classical case of oscillating charge that emits radiation of the same frequency as the photons impinging on it. This is known as

"Thomson scattering". Also scattering can be from bound electrons in an atom of atomic number Z and in this case, both the atomic number of the atom and momentum transfer q must be taken into account. This is usually expressed as a function F (q, Z) known as the atomic form factor. This scattering is known as "Rayleigh scattering", A detailed coverage of both interactions is given in the next chapter.

Since scattering is coherent, the scattered waves will retain the same wavelengths, as the incident waves and a definite phase relatjon between them will exist. Interference effects will take place and their nature will .depend on the electron distribution of the target medium. Interference can be attributed to be due to three basic routes: first between scattered waves of electrons in the same atom of object molecule, secondly between scattered waves of electrons of neighbouring atoms within the same object molecule (interatomic), and thirdly between scattered waves of different molecules (intermolecular) .

Furthermore, if the object material has some regular order, be it short or long order.

then interference can occur between coherently scattered X-rays photons from adjacent atomic planes, at some small angle e. Diffraction will then' occur and is governed by Bragg law which is given by .

n A == 2d sin ~

2

5

( 1. I )

(30)

where n IS tne oraer or {ne UllrraClIUfI, A l~ lilt: Wtlvt:lt:lllS111 VI 1l1vlUvllL ./\.-I"Y I-'"VLV", V I'>

the scattering angle, and d is interatomic spacing of the material. This equation can be expressed in terms of energy as follows

1

E

2d e

---sm

n h c 2

( 1.2)

where E is the energy of the incident X-ray photon, h is Planck's constant and c is the velocity of light.

The diffraction pattern obtained is composed of the energy spectrum of the incident X- ray source with the diffraction effects superimposed upon it. This diffraction pattern will be a characteristic ofthat object material.

Inspection of Equation 1.1 and Equation 1.2 shows clearly two distinctive methods of obtaining diffraction patterns. Keeping the incident wavelength A of X-ray photon fixed by the use of monoenergetic photons and sweeping the various angles

e

will give a diffraction pattern. This technique is known as the angular dispersive method and it is common in the field of crystallography. The alternative method is to keep

e

fixed at a given angle and vary the wavelength of the X-ray source and this usually done by employing a polyenergetic X-ray source where the various wavelengths exist together.

via the use of an X-ray tube. This technique is known as the energy dispersive method and will be used in this work.

Therefore, the phenomenon of Low Angle X-ray Scattering (LAXS) or Energy Dispersive X-Ray Diffraction (EDXRD) can be exploited to characterise materials of low atomic number Z that have some order in their structure. This is done by obtaining a diffraction pattern, a "signature" pattern specific of the material under investigation since it depends on its molecular structure. X-ray diffraction effects although more pronounced in crystalline substances than amorphous substances, do not only result

6

(31)

from separations of atomic planes within the crystal, but occur due to any appropriate separation of electrons (Royle and Speller, 1995).

Giessen and Gordan (1968) earlier investigated this phenomenon of Low Angle X-ray Scattering (LAXS), by irradiating powdered samples with polychromatic radiation fi"om an X-ray tube. The scattered X-ray spectra at low angle (~ 10°) were collected using a semiconductor detector and the lattice spacings of the samples were then deducted.

Energy Dispersive X-Ray Diffraction (EDXRD), employing low angle X-ray scattering from synchrotron radiation was used by Bordas et

az.

(1976) to study biological samples. This LAXS technique is used to investigate the bulk structure of materials.

particularly with low Z materials, that have some local order.

There is another technique, which is reported t;:xtensively in the literature by many authors such as Guinier and Fournet (1955), l(aelble (1967), and Glatter and Kratky (1982), namely Small Angle X-ray Scattering (SAXS) which should not be confused with LAXS. Though they are similar in certain general aspects, SAXS is used to investigate particle size and scattering is due to the particle and not to the internal structure it possesses and therefore Bragg diffraction cannot be employed. In addition, SAXS experiments employ angular dispersive method in its analysis.

1.4 Applications of LAXS

Since in LAXS the scattered X-ray photons have interacted with the target mediulTI then they carry with them information- relating to that mediulTI which cannot be said about transmission based techniques. The phenomenon of low angle X-ray scattering (LAXS) or energy dispersive X-ray diffraction (EDXRD) has some solid theoretical and experimental support to be exploited in the field of material identification. It is not' surprising to see that the first application of low angle X-ray scattering was a medical

7

(32)

application, and in the field of radiology in particular, since most of the previously mentioned works were in the field of radiology too. Harding et a1. (1985, 1987) experimented on a computed tomography imaging system based on low angle X-ray scattering.

The applications of low angle X-ray scattering may be categorised mainly into two fields: the medical and industrial. The development of the LAXS technique in these fields will be discussed in some detail. The medical field includes computed tomography, bone mineral density determination, characterisation of biomedical materials and imaging, and characterisation of related materials. The industrial field includes the studies of food contaminants, spices, explosives, and other materials of interest.

1.4.1 Computed tomography

Coherent X-ray scattering in computed tomography was covered by several authors such as Harding et al. (1985, 1987, 1990), Westmore et al. (1995, 1997), Barroso el al.

(1998), and Hall et al. (1998).

1.4.2 Bone analysis and mineral density determination

As discussed previously, almost all the work on the measurement of bone mineral density was done using gamma-rays as the source of radiation. However, in the work done by Webster and Lillicrap (1985) a heavily filtered X-ray beam was used to determine bone mineral density. The LAXS technique for bone analysis was utilised 'by Royle and Speller (1991, 1995), Farquharson et al. (1997), Farquharson and Speller (1998) and Allday and Farquharson (200 I).

8

(33)

1.4.3 Characterisation of biomedical materials and diagnostic radiology

There are many documented research in these areas using coherent X-ray scattering such as Bordas et af. (1976) (rat tail tendon), Johns and Yaffe (1983) (water), Morin and Ben'oir (1983) (water), Muntz et af. (1983) (perspex), Neitzel et al. (1985), Kosanetzky et al. (1987) (muscle), Evans et af. (1991), Speller and Horrocks (1991), Royle and Speller (1995) (bone), Chapman et af. (1997), Tartari et al. (1997), Byng et af. (1998) (breast tissue), Peplow and Verghese (1998), Bradley et al. (1999b), Elshemey, el al.

(1999), Kidane et al. (1999) (breast tissue), Royle et al. (1999), Barroso et al. (2000), Desouky et al. (2001) (blood), Elshemey et al. (2001) and Poletti et al. (2002) Details of some of the above authors can be seen on chapter three

1.4.4 Characterisation of other materials

,

The materials covered in this section are medical substitute material or other non- medical materials such as Pt, Au, SiC, plastics, stainless steel, oil etc. Authors who reported in this area are: Giessen and Gordan (1968), Kosanetzky et al. (1987), Zhu el al. (1994), lwanczyk et af. (1995), Westmore et al. (1996), Peplow and Verghese (1998), Bomsdorf (1999), Ltlggar et al. (1999) and Bomsdorf and Kosanetzky (2000).

See chapter three for more details.

1.4.5 Food industry

Measurements of contaminants in food were studied by authors such as Martens et al.

(1993) and Bull et al. (1997). Spices were studied using the LAXS technique by Desouky et a1. (2002).

1.4.6 Detection of explosives

There are several methods, which can be employed in the detection of explosives.

Summarised accounts of such methods and the vital role they play in airport security

9

(34)

',,'

.;:<-

.,,',

;(

have been reported by Stix (1992), George (1996), Nelms et af. (1999) and Speller (2001). The low angle X-ray scattering technique was employed in the detection of explosives by several authors such as Luggar et al. (1997), Luggar (1998), Luggar e/ 01.

(1998), Malden and Speller (2000) and Hastings et al. (2001). A good review on the above material can be found in the paper written by Luggar and Gilboy (1999).

1.4.7 Others

Theoretical treatment and other experimental aspects of the subject are well covered by the following authors Kissel et al. (1980), Roy (1980), Pratt (1983), Kane et al. (1986), Bradley et al. (1989), Saha (1995), Luggar et al. (1996), Farquharson et al. (1997), Rao et al. (1997), Luggar et al. (1998), Bradley et af. (1999a), Bradley et af. (1999b), Roy e/

af. (1999), Sidhu et af. (1999), Tartari (1999); Carney (2000), Tartari et al. (2000) Carney and Pratt (2001), and Tartari et al. (2002).

1.5 Scope of work

The scope of this work can be summarised in the following points:

• Characterisation of materials using a LAXS system comes 111 as a natural research project in the research scheme of the biophysics group at the school of physics, USM.

• Set up of the system is considered the first phase to be undertaken in the project.

This phase involves the individual testing of the equipments in the LAXS set up;

the X-ray machine, the X-ray photon detector and the supporting electronic gadgets.

• The initial phase also includes the selecting and fabrication of collimators,' collimators stands, movable arm for selecting angles and shielding.

10

(35)

• Experimental works were carried out on all the above aspects to determine their features and working conditions and hence evaluate each component individually and as part of the designed scattering scheme.

• The second phase of the project involves experimental work on the previously examined LAXS system setup using a standard crystalline material. Calcium carbonate powder was employed for this purpose.

• Parameters that affect the performance of the LAXS system were studied extensively and evaluated in order to optimise the best working condition of the system. The main parameters studied were: current, applied voltage, type and size of collimation system and time of exposure.

• The third phase of the projects deals wjth some applications of the LAXS system.

1.6 Objectives

The objectives of this work are to design an LAXS system, optimise it and utilise it in several applications, which were categorised as follows:

(i) Scattering from pure solids, compounds and mixtures (ii) Scattering from powders and liquids

(iii) Scattering from some biomedical materials

(iv) Scattering from simulated bone phantoms to study changes in bone matrix densities and cortical bone thicknesses.

(v) Study of some physical factors that effect sensitivity of LAXS.

(vi) Evaluation of interatomic spacings of certain substances.

(vii) Determination of linear differential scattering coefficient of some biomedical substitute materials.

11

(36)

CHAPTER TWO Theoretical Background

2.1 Interaction of X-rays with matter

An X-ray photon can interact with the medium it is traversing by many processes. In general, X-ray photons can be either absorbed or scattered. A collimated beam of X-ray photons has an exponential absorption nature, since each X-ray photon is absorbed or scattered in one single event which means that any photon, in the incident beam, passes the material had no interaction what so ever. The absorption law can be written as follows

I

(2.1)

where,10 is the initial intensity,1 intensity after passing a medium of thickness x, a,nd

~l is the linear attenuation coefficient. The possible processes of X-ray photon interactions can be deducted from the classification done by Fano (1953), which depends on both the type and effect of the interactions as seen in Table 2.1.

12

(37)

1 aOle L.1. 1 ype and ettect or possi ble interaction processes Type of interaction

1. interaction with atomic electrons 2. interaction with nucleons

3. interaction with electric field surrounding nuclei or electrons

4. interaction with meson field surrounding nucleons

Effect of interaction a. complete absorption b. elastic (coherent) scatteri ng c. inelastic (incoherent) scattering

There are twelve combinations between the two columns representing the possible interaction processes that can be obtained .. Some processes dominate over others depending on the energy range. The processes of interest can be listed as follows:

(i) Photoelectric effect (1 a) (ii) Compton scattering (I c) (iii) Pair production (3a) (iv) Rayleigh Scattering (I b)

(v) Nuclear Thomson scattering (2b) (vi) Delbruck scattering (3b)

(vii) Nuclear resonance scattering (2c) (viii) Photo disintegration of nuclei (2a) (ix) Meson production (4a)

I I

I

In the energy range from a few keV up to a few MeV, the most common processes are the first three processes listed above in addition to the Rayleigh scattering process. A brief description of those processes, which are considered to be useful is given below.

13

(38)

2.1.1 Photoelectric effect

This process occurs in the energy range I - 100 ke V, and it involves the removal of bound electrons from the atoms upon the absorption of all the incident photon energy.

The energy of the photon, E should be equal to or larger than the electron binding energy, BE. For the latter case, an electron will be ejected with kinetic energy, T given by

T:=E-BE

(2.2)

2.1.2 Compton scattering

This process dominates at intermediate energy, and it deals with the scattering of X-ray photons by atomic electrons that are assumed free, therefore, it occurs at energies greater than the binding energy of the electrons. For an X-ray photon with energy, E . it will scatter, upon striking a target electron, through angle, 8, made relative to the original direction and with energy

E' ,

given by

E'= E

1 +

- - - 2

E

(l -

cos e) rna

C

where,

rna

represents the mass of electron and c the velocity of light.

The differential total Compton cross section is given by

d

(5 KN

dO. S(q)

(2.3a)

(2.3b)

where the first term refers to the Klein-Nishina function and the second term is the incoherent atomic scatter function.

14

(39)

2.1.3 Pair production

When the photon energy exceeds 1.02 MeV (ma c2), annihilation of the photon occurs with the appearance of electron - positron pair in its place. The electron - positron pair has a total kinetic energy equal to the energy of the vanished photon.

(2Aa)

where

Te -

and

T e

+ are the kinetic energies of the electron and positron respectively. This process will only take place greatly in the field of the nucleus and takes over as the dominant process as the photon energy increases.

2.1.4 Rayleigh scattering

The Compton scattering process is an inelastic (incoherent) interaction where the scattered photon suffers deviation from its origiqal direction, and carries a lower energy than the incident one. The Rayleigh scattering process, on the other hand, is an elastic (coherent) interaction where the incident photon does not lose any energy, but suffers deviation of small angles from its original direction so that no atomic excitation or ionization occurs to the atom. The Rayleigh scattering cross section, (White, 1950), of great importance at small photon energies, but it diminishes at higher energies due to the increased dominance of the inelastic process. The differential elastic cross section is given by

d

C5 Th

dO

F

2

(q)

(2Ab)

where the first term refers to Thomson cross section and the second term is the form factor scatter function.

Elastic scatter is predominant at small angles and in the diagnostic energy range or low, momentum transfers that is single coherent scatter is much more intense than single

15

(40)

Compton scatter. Within this region, single inelastic scatter is suppressed due to electron binding effects. Nevertheless, this is in conflict with the fact that the total inelastic cross-section is greater than the total elastic scatter cross-section (about 10 %). For example, the partial interaction cross-sections for oxygen over the diagnostic energy region (0-100 ke V) shows photon attenuation is dominated by photoelectric absorption and incoherent (Compton) scatter and at no point is elastic scatter the major influence.

This conflict is resolved by observing the differential cross-sections for scatter in the momentum range below 0.5 A-I (corresponding to 10° at 70 keY) where coherent scatter is the dominant mechanism for photon scattering. By comparing both the coherent form factor function and the incoherent scattering function below the momentum transfer value stated above, it can be said that the coherent scatter is confined to a narrow forward scattering peak and the Compton scatter vanishes as the momentum transfer approaches zero due the incoherent scattering function. A detailed outline of this process will be given later.

2.1.5 Nuclear Thomson scattering

This is another type of elastic scattering which, combines coherently with Rayleigh scattering. It is detected at high energies, and attributed to the scattering from the nucleus, which is considered to be a point charge. This interaction has small contributions due to the large mass of the nucleus, (Davey, 1953; Strickler, 1953;

Wilson, 1953).

2.1.6 Delbruck scattering

Delbruck scattering is also an elastic (coherent) scattering process, and is due to the.

formation of virtual electron-positron pair in the field of the nucleus followed by annihilation in the same field. It takes place at energies above 1 Me V.

16

(41)

2.1.7 Nuclear resonance scattering

This process is an elastic one and occurs at energies above 1 MeV. It involves the excitation of the nuclear levels by the impinging photon followed by emission of this excitation energy, and it also involves nuclear resonance giant dipole transitions.

2.1.8 Photo disintegration of nuclei

This process is referred to as the nuclear photoeffect, it takes place when the energy of the photon is larger than the nucleon separation energy and it is restricted to energies above 8 MeV. This absorption process has very small cross sections.

2.1.9 Meson production

Meson production is an absorbing process, which requires high photon energy in the range of about 150 MeV. The cross section associated with this process is negligible.

2.2 Principles of X-ray scattering

2.2.1 Introduction

X-rays are electromagnetic waves that consist of electrical fields,

E

and magnetic fields,

B

perpendicular to each other and to the direction of propagation.

Electromagnetic waves can be represented by a plane wave expressed in terms of the electric field vector

E .

For linearly polarized electromagnetic waves, it can be written in general in the form

(2~5)

where,

k

is wave vector along the direction of propagation and its magnitude k

=

27r is called the wave number, Ie is the wavelength. Eo, is the amplitude of the

A

17

(42)

A

electric field, co is angular frequency, and u, is a unit vector, which represents the polarization of electric field. If the direction of propagation is assumed to be along the z-axis then Equation (2.5) can be simpl ifled by taking its real part, to

E (z , t) = £iE

0 SIll

(kz -

(j)

t)

(2.6) The above description is a classical one. The quantum mechanical conception of an electromagnetic wave is one consisting of photons each carrying definite amounts of energy called "quantum". The energy of the photon E is given by

E = nm (2.7)

The photon also has a momentum

P

associated with it given by

P = nk'

(2.8)

The intensity

1

of an X-ray beam equals the number of photons per second that transverses a given area. Classically, the intensity of X-ray beam is proportional to the square of the electric field.

(2.9)

2.2.2 Scattering of X-rays by single electron "Thomson scattering"

When an X-ray photon of low energy (tz OJ

« me

2 ) strik,es a single electron, the electric field of the incident electromagnetic wave will exert a force on it. According to the classical theory of radiation, the electron will accelerate and therefore will emit an electromagnetic radiation of the same wavelength as the incident one that represents the scattered wave. This is a description of an elastic process. Note that in this classical.

view momentum transfer is ignored. In fact, some momentum is bound to be transferred to the electron since any photon has momentum given by Equation (2.8).

18

(43)

If the electron IS bouno to an atom, tne InClOem pnman s momemUIIl WIll ue Llall::'lellCU

not to the electron concerned but to the whole atom. In this case, the energy loss will be given by

E

loss

p2 2M

where M is the atomic mass and not the electronic mass mo.

(2.10)

Since

M > > m

0 , then the energy of the scattered photon is almost unchanged from the incident one and the process remains an elastic process. An elastic process, therefore, can involve momentum transfer to some extent.

Consider a free electron that is struck by an electromagnetic plane polarised radiation with its electric vector in the y-z plane given by

E.

In (2.11 )

The electronic charge will be accelerated back and forth along the y-axis in very small amplitudes. The field, at some observation point P, which is at a distance r from the electron and makes an angle

e

with respect to the direction of travel, must be calculated.

The observer can be located either in the y-z plane (i.e. in a plane of polarisation of the incident wave) at PI or in the x-z plane (i.e. in plane perpendicular to the plane of polarisation) at P2, as in Fig. 2.1.

The radiated field at point P is given by

(2.12)

19

(44)

x

P2

z

Fig. 2.1 Coordinate axes and observer points for EM wave of electric field E.

where, a (t - !.--) is the acceleration at time (t - !.--), which is called the retarded

c < c

acceleration, and should be the component of acceleration perpendicular to the line of sight (F eynman et al., 1965). In this case it equals to a (t - -) cos r

e.

Therefore,

c Equation (2.12) becomes

(2.13)

It can be noted that if

e =

1f then a

=

0 and hence no acceleration is observed, and 2

ifB

=

0, the full acceleration is observed at that position. Therefore, if the observer is at position P2, the acceleration at any point in that plane is perpendicular to the line of sight and the radiated field will be give by Equation (2.12). The acceleration is related to the electric field by the following relation

20

(45)

a

- - E i l 1 - e ~

me

())

Using Equation (2.11),

k

= - and then rearranging to obtain c

r - e

~ 'k

aCt - -)

= - - E i n

e'

r

C

me

Therefore, Equation (2.12) becomes

r

And Equation (2.13) becomes

E

in

cose

r

(2.14)

(2.15)

(2.16)

(2.17)

The first term is defined as

ra

the classical electron radius or sometimes it is known as e-

,

Thomson scattering length r 0

= =

2.82 x 10 -15 m, and the second

Rujukan

DOKUMEN BERKAITAN

If we ignore the Rayleigh elastic coherent scattering, the total energy absorption coefficient involves only three processes that lose some fraction of the incident energy which

In this study, the scattering angles ranged from 30 0 to 140 0 with the detection using Ge(Li) detector. Investigation of electron binding effect to the incoherent scattering

Determination of integral Compton-scattering cross sections at 279-keV gamma rays from K-shell electrons in Fe, Ni, Cu, Zn, As, Se, and Br.. Gamma-ray attenuation coefficients of

The former calculations‟ cross sections are closer to the CC(5,6) K cross section at energies higher than 12 eV. We can observe that the CC5 E calculation overestimates

Figure 6.48 Differential cross section of neutron candidates with respect to its measured momentum momentum (pb/GeV) vs its energy

Based on pooled cross-section time- series data regressions, the real effective exchange rate (a measure of external competitiveness) is found to be strongly related to

This paper is primarily to find out from the cross-section of experienced Malaysian construction firms in international market Grade 7, Class A from all over Malaysia on

Keywords: Lyari River, Strom Flow, Hydraulic Characteristics, L-Section and Cross-Section Survey, Channel