• Tiada Hasil Ditemukan

o Water quality unit is one of the main scopes of Environmental Health Officer in Health District Office.

N/A
N/A
Protected

Academic year: 2022

Share "o Water quality unit is one of the main scopes of Environmental Health Officer in Health District Office. "

Copied!
5
0
0

Tekspenuh

(1)

V2TGS 6/10/2018

Blueprint Presentation

ENV 600-Technology Entrepreneunhip

Portable Water Sampling Kit Wan Wan Enterprise

FOR BRIGHTER FUTURE

|P W ^ m

Wan M u h a m a d Norazwan Bin Wan Abu Bakar

2015221448

Chief Excecutive Officer

Mohd Azmieludin Bin Mohd Suhaimi

2015444432

Chief Operation Officer

Nik Muhammad Hanif Bin Nik Man

2015276756

Chief Financial Officer

1

(2)

o Water quality unit is one of the main scopes of Environmental Health Officer in Health District Office.

o The main objective of water quality unit is to elevate the health of the public by ensuring that the supplied drinking water is safe and acceptable to the consumers.

o The main goal of this project is to create a portable water sampling unit that can run the test for all Vpf&e^fyii physical parameter of water that is residue for chlorine, the temperature of water, Ph of the water, and water turbidify.

o Environmental Health Officer (EHO) needs to carry 3

larger sampling unit that tests all of this parameter

nowadays.

(3)

PRODUCT DESCRIPTION

D r\ A

B

, Test p r o b e .

I Probe c o n n e c t e r (plug-in)

Buttons Screen Built-in batteries.

4 in 1 probe

^ P *

• This probe c a n test 4 parameter at the same time while the previous portable sampling equipment only c a n test the 1 parameter at one time such as Ph a n d temperature.

• High durability to temperature and need longer time to calibrate the probe sensor.

(4)

6/10/2018

1 water sampling bottle.

i

J

Previous portable sampling bottle, it needs 3 different bottles to run water sample physical test while for the new product it only needs water sampling bottle to test all the parameter.

A d v a n c e d electrical board

This a d v a n c e board will run all the test at the same time.

It uses a new processor that take less time to get the result.

Processor : Qualcom Snap Dragon V.4 ( 20K Cache, 350 MHz)

(5)

6/10/2018

Built-in battery

> 2750mAh lithium ion (Li-ion) will be used for powering the equipment.

> The capacity of the battery c a n last for 8hours for standard use of the equipment.

MARKET ANALYSIS

Customers

The target market for this product is based on agencies that take water sample

Market size

o Estimated of prospect buying (35%) = 173 X 0.35 = 61 pes

o From the number of prospect that is buying, the estimates sales forecast

61 XRM 15,050 = RM 918,050

Rujukan

DOKUMEN BERKAITAN

Finally, there is the method of unobtrusive control (Tompkins & Cheney, 1985) which is described as getting employees to control themselves. It is a process by which members of

The price to make this project is a low cost hourly chime that is has 16 different tone that can enhance the charm o f your digital clock.. This unit can

Consider the heat transfer by natural convection between a hot (or cold) vertical plate with a height of L at uniform temperature T, and a surrounding fluid that

BAKAS (Water supply and environmental sanitation) unit of Ministry of Health was first introduced in 1974 for controlling water and vector borne diseases by providing safe

will have relatively more volatile prices. Terrace houses provide some land in front and back while semi-detached have land space on the side of the building. Of course, the

On the auto-absorption requirement, the Commission will revise the proposed Mandatory Standard to include the requirement for the MVN service providers to inform and

8.4.4 Three (3) months after the receipt of the Notice of Service Termination from the MVN service provider, the Host Operator shall ensure that the unutilised

The problem of water pollution caused by the contamination of water sources with bacteria is one of the main factors contributing to the human health risk.. The